Centeron Wireless Tank Monitoring System
Centeron Pressure Monitors accurately measure tank product levels in vented vessels, and send data
to a Centeron controller using robust Direct Sequence Spread Spectrum (DSSS) wireless technology.
The Pressure Monitor is a simple, cost-effective solution for remote level measurement in medium
to large storage tanks up to 40 ft. or more in height.
- Suitable for a wide variety of fluids including hydrocarbons,
chemicals and water/wastewater
- Installs easily in minutes
- No calibration required
- Low maintenance
- Wireless communication and battery power eliminate
costly electrical wiring required by traditional tank
measurement systems
- Submersible and external tank mounted sensors

- Measurement range: 44 feet
- Accuracy: +/- 1% at +25C
- Unobstructed Range: 1 mile
- Obstructed Range: 500 ft.
- 3 year battery life, low battery indicator
- Operating temperature range: -40C to +80C (-40F to +176F)
- Compensated temperature range: -20C to +75C (-4F to +167F)
- ETL/cETL certified intrinsically safe for use in Class I,
Division 1, Group D Hazardous Locations
- FCC Part 15 approved
- NEMA 4 Enclosure
|
| 
|
|
The Centeron System
We start with the monitor. It's wireless, so no special know-how or tools are needed to install
it. It's powerful, too. Our DSSS radio technology is far superior to the narrow bandwidth radios
found in other wireless systems. That means the alarm signal gets through even in the harshest environment.
The monitor sends the tank level data to the controller. The controller collects the data then sends
it to the Centeron Data Center. From there, you can retrieve your info anytime, wherever you are.
Just think what that means to your business. You can eliminate the fear of costly overfills or undetected
leaks. Eliminate manual monitoring of your tanks during every fill. Eliminate the need for manual
leak inspections. Let Centeron do it for you 24/7. Centeron puts you in control so you can manage
your business better.
|
ETL/cETL Marked Intrinsically Safe apparatus for use in Class I, Division
1, Group D hazardous locations, conforming to ANSI/UL 913 and CAN/CSA C22.2 No. 157.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference
and (2) This device must accept any interference received, including interference that may cause
undesired operation. FCC Part 15 Registered: NU9TX0625-0300 |
|